[. . . ] The SKP 100 g plugon transmitter converts any wired microphone into a radiomicrophone and the SK 100 g bodypack transmitter is the perfect companion for the ME 2 or ME 4 clipon microphones, the ME 3 headmic or guitar cables. Transmitters and receivers of the 100 g series have nine frequency banks with 4 presets each for direct channel selection. The receivers feature a scan function that automatically scans the selected frequency bank for free frequencies. [. . . ] Transmitters and receivers have large backlit displays with peak-hold display. The EM 100 g`s audio outputs are available both as balanced XLR and 1/4" sockets. 518­554, 626­662, 740­776, 786­822, 830­866 MHz Transmission/receiving frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Compander . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HDX Signal-to-noise ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 dB Audio frequency response. . . . . . . . . . . . . . . . . . . . . . . . . . . . 40­18, 000 Hz Pilot tone squelch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . can be switched off Receiver Scan function. . . . . . . . . . . . . . receivers scan one frequency bank Adjacent channel rejection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 65 dB Intermodulation attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 65 dB Sensitivity (with HDX, at peak deviation, 52 dBArms S/N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . super-cardioid ew 122 g Presentation Set, includes bodypack transmitter, clip-on mic (cardioid) and rack-mount receiver ew 152 g HeadSet, includes headmic (super-cardioid), bodypack transmitter and rack-mount receiver ew 172 g Instrument Set, includes bodypack/instrument transmitter, guitar cable and rack-mount receiver ew 135 g Vocal Set, includes hand-held transmitter (cardioid, dynamic) and rack-mount receiver ew 145 g Vocal Set, includes hand-held transmitter (super-cardioid, dynamic) and rack-mount receiver ew 165 g Vocal Set, includes hand-held transmitter (super-cardioid, condenser) and rack-mount receiver ew 112-p g Camera Set, includes portable receiver, bodypack transmitter and clip-on microphone (omni) ew 122-p g Camera Set, includes portable receiver, bodypack transmitter and clip-on microphone (cardioid) ew 135-p g Camera Set, includes portable receiver and hand-held transmitter (cardioid, dynamic) ew 100-ENG g Camera Set, includes portable receiver, bodypack transmitter with clip-on microphone (omni) and plug-on transmitter for wired dynamic microphones j j j j j j j Microphone heads for SKM 100 g hand-held transmitter MD 835 Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dynamic Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 dB Pick-up pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cardioid MD 845 Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dynamic Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mV/Pa Max. SPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 dB Pick-up pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . super-cardioid ME 865 Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . condenser Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 mV/Pa Max. [. . . ] SPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 dB Pick-up pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . super-cardioid ME 865 Transducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . condenser Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 mV/Pa Max. SPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 dB Pick-up pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]